IEC 60068-2-30 - Test Db: damp heat, cyclic

Damp heat, cyclic (Test Db) - condensation during daily temperature changes.

Rodzaj
Test methods and conditions
Organizacja
IEC, TC 104 Environmental conditions, classification and methods of test
Aktualne wydanie
Edition 4.0, 2025-08 (IEC 60068-2-30:2025); replaces Edition 3.0 from 2005 (IEC 60068-2-30:2005, EN 60068-2-30:2005 in Europe). European adoption: EN IEC 60068-2-30:2025
Status
current

What the test covers

A method for testing the suitability of components, equipment and other products for use, transport and storage under high humidity combined with cyclic temperature changes. The daily cycle causes water-vapor condensation on the specimen surface and reproduces enclosure “breathing” during temperature changes.

For small, low-mass specimens on which condensation is difficult to produce, the standard points to IEC 60068-2-38 as an alternative.

Why it matters

The test demonstrates that the product withstands repeated condensation and moisture ingress during day/night temperature changes, including moisture penetration into the enclosure during cooling. A reference without the upper temperature and number of cycles does not define severity; the combination is prescribed by the product standard.

The method checks behavior under cyclic humidity; long-term steady humidity is tested by Test Cab.

Test method

The specimen is stabilized in the chamber at 25 °C ±3 K, then humidity is raised to at least 95% RH and 24-hour cycles begin. Each cycle consists of a temperature rise to the upper value within 3 h ±30 min (humidity ≥95% RH, ≥90% during the last 15 min), holding at the upper temperature for 12 h ±30 min at 93% ±3% RH, then cooling to 25 °C ±3 K within 3–6 h and holding at 25 °C until the end of the 24 h period.

Variant 1 maintains ≥95% RH during cooling with a defined initial temperature-fall rate; Variant 2 permits ≥80% RH during cooling without a specified fall rate. The chamber maintains temperature within ±3 K and a difference between points ≤1 K, with no thermal radiation on the specimen; condensate (water resistivity ≥500 Ω·m) is continuously removed so that it does not drip onto the specimen.

Visual inspection and functional measurements are performed before testing; after testing, recovery is performed (standard or controlled: humidity reduced to 75% ±2% RH within 1 h, then laboratory temperature reached within the next hour) followed by final measurements, with humidity-sensitive parameters measured first, within 30 min.

Severity is defined by the combination of upper temperature and number of cycles, selected by the product specification.

Parameters and severities

  • upper temperature 40 °C: 2, 6, 12, 21 or 56 cycles (2005 edition)
  • upper temperature 55 °C: 1, 2 or 6 cycles (2005 edition)
  • lower cycle temperature 25 °C ±3 K
  • humidity at high temperature 93% ±3% RH; during rise and at low temperature ≥95% RH
  • Variant 1: cooling at ≥95% RH; Variant 2: cooling at ≥80% RH
  • cycle duration 24 h: rise 3 h ±30 min, upper-temperature hold 12 h ±30 min, fall 3–6 h

What to check in the datasheet

Look for the upper temperature (40 or 55 °C), number of cycles and variant (1/2); without all three, “IEC 60068-2-30” describes only the procedure. Distinguish it from Test Cab (IEC 60068-2-78, steady humidity) - both often appear together in datasheets but test different degradation mechanisms.