UL 497 - Surge protectors for communications and fire-alarm circuits

Surge protection for telecommunications and fire-alarm circuits, US and Canadian markets; Part B - data-transmission and fire-alarm circuits.

Rodzaj
Approvals, marks and certification standards
Organizacja
UL Standards & Engagement (ULSE)
Aktualne wydanie
UL 497B Edition 4 (2004-06-14)
Status
current

What the standard covers

UL 497B covers protectors for data-transmission and fire-alarm circuits: single- and multipair spark-gap, gas-discharge and solid-state arresters, with or without fuses, protecting equipment, wiring and personnel against excessive voltages and currents of atmospheric origin.

The standard excludes protection of primary distribution systems, antenna discharge units, building lightning-protection systems and telephone-line protectors (which are covered by UL 497 / UL 497A).

What this means for selection

A signal-line protector listed to UL 497B is approved for use in fire-alarm and data circuits in the US/Canadian market, which is relevant when exporting railway signalling or lineside telecommunications equipment.